TDM counter retrieval which previously could have caused a crash in the command server, resulting in management unresponsiveness. Does not impact Eth only datapath.
New T1/E1 binary files for reduced voltage. Voltage should be ~5.4 volts peak-to-peak now. Note: Because of binary change, radios will not link with different firmware.
FTP operations restored which had not been included in the 1.3.2 release.
Exit from CLI view node is not a permitted command. Previously this would cause future telnet sessions to be rejected.
This release does not include a PIC image to eliminate the possibility of a PIC upgrade failure and PIC 60 and 62 are both supported.
Condensed instructions: (detailed instructions are available in the release notes)
Transfer the image upgrade file to the radio. (Do not un-tar the file.) Either download the file from here and transfer with TFTP, or pull it directly from our FTP server.